Attack Model:
|
DP 75 Profi
|
DP 95 Profi
|
Nominal output
|
75 kW (256 KBTU)
|
95 kW (325 KBTU)
|
Range of output setting (PROFI version)
|
30-75 kW (102-256 KBTU)
|
38-95 kW (140-325 KBTU)
|
Prescribed chimney draught
|
26 Pa
|
28 Pa
|
Max water operation overpressure
|
250 kPa (35 PSI)
|
Pressure loss of water (T 10K)
|
8.8 kPA (1.3 PSI )
|
Pressure loss of water (T 20K)
|
1.6 kPa (0.23 PSI)
|
Diameter of flue gas outlet
|
200 mm (8")
|
Loading chamber dimensions
|
|
L 41"x W 21"x H 31"
|
Diameter of C.H. flow connection
|
2 "
|
Diameter of C.H. return connection
|
2 "
|
Protection level
|
21 IP
|
Maximum electric load
|
4 A
|
Boiler class
|
3
|
Flue gas temperature by nominal output
|
350 °F
|
Flue gas flow by nominal output
|
0.033 kg/s
|
0.035 kg/s
|
Average wood consumption
|
18.7 kg/h
|
29.2 kg/h
|
Max wood log length
|
1000 mm (40")
|
Operation time by max.output
|
2.5 h
|
3.5 h
|
Volume of water in boiler
|
164 l (43 Gal)
|
250 l (65 Gal )
|
Recommended accumulation tank min. volume
|
500 Gal
|
Range of water temperature setting
|
65-90 °C ( 150 F to 195 F)
|
Current carrying capacity of boiler regulator´s contacts of (PROFI version)
|
115V/4A
|
Average wood consumption per season
|
1kW=0.9m3
|
Efficiency
|
86.2 %
|
80.6 %
|
Fuel
|
Seasoned Wood (can be mixed with coal 40%)
|
Electrical power connection
|
115V/60Hz
|
Weight
|
650 kg (1422 lb)
|
800 kg (1900 lb)
|
Heat-transfer surface
|
3.6 m2 (39 sq/f)
|
5.6 m2 (60 sq/f)
|
Max. noise level
|
65 dB
|
Feeding door size
|
235x445 mm ( 9.2" x 17.5")
|
Boiler width
|
27.5”
|
30"
|
Boiler height
|
57.5”
|
61"
|
Boiler depth
|
66”
|
66"
|