Features an adjustable flame spreader to allow tailoring of the flame size to the combustion chamber. Fires from 50,000 to 250,000 Btu/hr. Power burner design will increase efficiency up to 30% over atmospheric gas burners. Available in 8″ air tube length.
Technical Properties:
Minimum Btu/hr Input | 50,000 |
Maximum Btu/hr Input | 250,000 |
Voltage | 120 Volt, 60Hz |
Gas Pressure Required | Natural gas – 4.5″ W.C. LP gas 11.0″ W.C. |
Ignition Source | Standing pilot or Direct ignition(recommended) |
Gas Valve | 24 Volt |
Combustion Chamber | |
Floor Area | Minimum 0.6 sq. in./1000 Btu/hr Maximum 0.9 sq. in./1000 Btu/hr |
Gas Connection | 1/2″ NPT |
Air Tube Diameter | 4″ |