Natural Gas or Propane Burner

$690.00

Description

Features an adjustable flame spreader to allow tailoring of the flame size to the combustion chamber. Fires from 50,000 to 250,000 Btu/hr. Power burner design will increase efficiency up to 30% over atmospheric gas burners. Available in 8″ air tube length.

Technical Properties:

Minimum Btu/hr Input 50,000
Maximum Btu/hr Input 250,000
Voltage 120 Volt, 60Hz
Gas Pressure Required Natural gas – 4.5″ W.C.
LP gas 11.0″ W.C.
Ignition Source Standing pilot or
Direct ignition(recommended)
Gas Valve 24 Volt
Combustion Chamber
Floor Area Minimum 0.6 sq. in./1000 Btu/hr
Maximum 0.9 sq. in./1000 Btu/hr
Gas Connection 1/2″ NPT
Air Tube Diameter 4″