Characteristristics:
- Thermostatic draught control that governs insertion of air under the grille.
- Secondary air control
- Flue draught control
- Boiler temperature thermometer
Main characteristics:
- High combustion performance
- Excellent resistance to corrosive agents
- Combustion chamber of a regular shape to ensure maximum fuel load
Ease of loading and autonomous operating time:
- Spacious fire box to increase autonomous operating time
- Spacious loading door
- Lever for loading door opening with an anti-burn soft rubber protection
Optimized combustion:
- Designed to ensure uniform thermal load
- Distribution of secondary air with pre-heating
- Bathed and finned grille
- Fire box with spacers between load and walls
- Rear element with rungs on a fire side and intermediate elements
Smoke path in three sections:
- Uniform air entry under combustion grille
- Less thermal stress
- Distribution of unburned residues
Three burning stages
- Stage1
The combustion by-products are carried by a special passage obtained in the rear element. In the same area, very hot secondary air is inserted which favours complete oxidation of the gases.
- Stage2
Gases from the rear element are sent to a wide-finned, self-cleaning zone, in the same time they make a favour entry into the third section.
- Stage3
The third section directs the smoke towards the
flue with adjustment shutter and door for cleaning.
Eko Coal - CAST IRON SOLID FUEL BOILERS - technical data`
|
Description
|
Unit of measure
|
Eko Coal21
|
Eko Coal26
|
Eko Coal 31
|
Eko Coal 36
|
| Fuel |
|
Coal
|
| Negative pressure at flue (Min / Max) |
mbar
|
0.1/0.3
|
| Maximum acceptable temperature |
oC
|
95
|
| Operating temperature (range) |
oC
|
40÷90
|
| Minimum permissible return temperature |
oC
|
50
|
| "PMS" maximum operating pressure |
bar
|
|
| Duration of one load |
h
|
>2
|
| Diameter of flue fitting |
mm
|
180
|
| Unit class* |
no.
|
1
|
| Water side pressure drop (D t= 150C) |
mbar
|
12
|
15
|
18
|
20
|
| Water side pressure drop (D t= 200C) |
mbar
|
10
|
12
|
14
|
17
|
| Water capacity in a boiler |
l
|
35
|
41
|
47
|
53
|
Dimensions:
|
Model
|
Number of elements
|
Nominal average
thermal power (Qn)
kW
|
Dimensions of door W x H
cm
|
Dimen. of chamber
WxHxD
cm
|
Volume of
loading /
combustion
chamber
l
|
Dimensions (mm)
|
Weight (kg)
|
|
Height (mm)
|
Width (mm)
|
Depth (mm)
|
| Eko Coal21 |
4
|
21,2
|
38 x 30
|
38 x 43 x 34
|
55
|
955
|
600
|
525
|
270
|
| Eko Coal26 |
5
|
26,2
|
38 x 30
|
38 x 43 x 45
|
73
|
955
|
600
|
635
|
315
|
| Eko Coal31 |
6
|
30,5
|
38 x 30
|
38 x 43 x 56
|
91
|
955
|
600
|
745
|
365
|
| Eko Coal36 |
7
|
35,2
|
38 x 30
|
38 x 43 x 67
|
109
|
955
|
600
|
855
|
410
|